First, the basic requirements of the economic operation of heat pump system: 1, as far as possible the use of high temperature heat source. 2, the actual temperature difference between heat source and heat medium is the lowest. 3, the heat source should meet the following requirements: --- In the highest possible heating temperature to provide the required heat. --- The cost of using the heat source is lower. --- Whether in the chemical or physical, heat exchange equipment does not have a negative impact. --- Heat conditions change, better adaptability. --- Conveying equipment such as fans, pumps and other energy consumption as low as possible. Second, the heat pump system compressor should meet the following requirements: 1, for the air source heat pump, tz = -35 ~ +15 oC and tl ≤ 65 oC range should be able to operate normally; compression ratio up to 9, there should be satisfactory Efficiency; the same time, there should be no excessive temperature overheating. 2, the inhalation of steam in the superheated and unsaturated state, the compressor is not affected by the quality of inhalation. 3, can withstand the rapid changes in work pressure, does not produce oil foam; oil should be returned to the crankcase with steam, and in the box with immersion heaters. 4, there should be good, reliable over-temperature, over-voltage protection device. Trouble-free operation time in more than 25000h. 5, Larger heat pump, should be equipped with a smooth and without loss of energy mediator. 6, Compressor equipped with motor, with a flat efficiency curve. Based on the above requirements, put forward the following recommendations: Heating Q = 0.5 ~ 500KW, the use of positive displacement. Heating Q> 500KW, the use of centrifugal. Third, the refrigerant flow control to the use of thermal expansion valve is appropriate, but should be "balanced hole" type, in order to maintain the pressure does not change with the change, but in the case of smaller pressure normal operation. Fourth, the economic judgments For a certain performance of the heat pump system, the following conditions are generally considered economical: there is a good source of heat as groundwater. The annual running time is not less than 2000h. COP values> 3 No heating is required for heating cycles based on summer cooling. Refrigeration equipment has been used in the occasion, such as cold storage, skating rink, supermarkets and so on. Waste heat available for use. Large internal waste heat within the building, it is possible to use the internal heat source to heat the building when the ambient temperature is below zero, such as department stores, theaters, computer rooms. Conversely, the economics of a heat pump in the following situations are not certain: for heating only. COP <3. Heat pump capacity is much larger than the heating load.
Each part has undergone strict quality inspection and is properly packaged to ensure safe transportation.
EUI EUP injectors are equipped on heavy equipments. Popular EUI EUP is Delphi E1&E3, Cummins M11, CAT C12/C13/C15/C18, Scania, Iveco etc.
Each part has undergone strict quality inspection and is properly packaged to ensure safe transportation.
EUI parts, Eui Eup Parts,Eui Eup Parts And Accessories,Eui Eup Parts Kit
CHENGDU UNICO MACHINERY CO., LTD , https://www.injectortestbench.com