H-150 slide valve vacuum pump troubleshooting

1. Vacuum is not high: (1). Pump leakage. (2) cartridge hole suction, appear mist: cleaning oil filter, check tubing, pumps. (3) pump oil pollution: open the gas valve running 1-2 hours or longer, or new oil. (4). Insufficient fuel, the oil level is too low: fuel. (5). Oil temperature is too high: Increase the amount of water, reduce the ambient temperature and inhaled gas temperature, eliminate occlusion, poor lubrication. (6). Exhaust valve damage: for the valve. (7). Exhaust valve spring damaged: renewal. (8) parts of the pump wear and tear, there are different sound, power abnormalities: dismantling inspection of the rotating parts. 2 oil leakage: check shaft seal, the sealing parts, adjust or change new. 3 noise: abnormal noise: check whether foreign objects fall into the pump chamber, bearings, pump drive without damage. Clear, trim, change new. 4 fuel injection: a large number of oil spouts: check the oil level is too high, such as too high, release; oil shield components, anti-injection components, etc. are intact. 5 Vibration: Vibration: Check the base is solid, fastening, the foundation is sufficient. Have bite, stuck in the early signs, adjust. 6 abnormal temperature pump bearing fever: a little loose belt, check whether the smooth flow of oil, cooling water enough. Fuel tank heat, exhaust valve overheating: reduce the inlet pressure, increase the amount of cooling water. 7 occlusion stuck: check whether foreign objects fall into, parts intact, lubrication is adequate, fuel, oil, pumps. 8 motor current is too large or fuse blown: check the current is too large reason, check the fuse capacity, adjust, change new.

Aluminum Camlock DC

Type DC Aluminum Camlock Coupling,Aluminum Camlock Couplings Type DC, Type DC Aluminium Camlock Coupler

Cixi Chengtuo Hardware Parts Factory , https://www.ibccoupling.com